4 resultados para Eccentric Exercise

em Indian Institute of Science - Bangalore - Índia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heat transfer in a MHD flow between two infinite eccentric disks rotating with different speeds is considered when the plates are maintained at different temperatures. The results for the corresponding nonmagnetic case presented wrongly by Banerjee and Borkakati [7] are corrected. It is observed that the eccentric rotation reduces the heat transfer on the disks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unsteady MHD flow of an incompressible, viscous electrically conducting fluid contained between two torsionally oscillating eccentric disks has been investigated. The state of uniform rotation of the central region visualised in the steady flow is seen to be absent in the case of oscillatory flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of an eccentrically inserted catheter on the peristaltic pumping in a tube is investigated under long wavelength, low Reynolds number assumptions. The radially asymmetric deformation of the wall arising through an eccentrically inserted catheter is taken into consideration by choosing an appropriate bipolar coordinate system. The effect of the position and size of the catheter on pumping characteristics is studied. The best performance of pumping is noticed at a certain position of the catheter. The size of the catheter, when placed eccentrically, alters the pressure signature significantly inside the bolus, unlike the concentric case discussed by Lykoudis and Roos (1971). Further, the maximum pressure rise in one period of the peristaltic wave is observed to decrease with an increase in the eccentricity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a multiple initialization based spectral peak tracking (MISPT) technique for heart rate monitoring from photoplethysmography (PPG) signal. MISPT is applied on the PPG signal after removing the motion artifact using an adaptive noise cancellation filter. MISPT yields several estimates of the heart rate trajectory from the spectrogram of the denoised PPG signal which are finally combined using a novel measure called trajectory strength. Multiple initializations help in correcting erroneous heart rate trajectories unlike the typical SPT which uses only single initialization. Experiments on the PPG data from 12 subjects recorded during intensive physical exercise show that the MISPT based heart rate monitoring indeed yields a better heart rate estimate compared to the SPT with single initialization. On the 12 datasets MISPT results in an average absolute error of 1.11 BPM which is lower than 1.28 BPM obtained by the state-of-the-art online heart rate monitoring algorithm.